We offer a lineup of signal converters tailored to various applications,
ranging from DC signals to temperature and rotational speed.
The Fine Series is a line of compact plug-in transducers designed to convert and isolate various measurement signals. The lineup includes a wide variety of models, such as isolators, distributors, temperature transducers, and speed transducers.
In addition to single-output models, dual-output models are also available, allowing signals to be distributed for control and monitoring purposes. Multiple units can be consolidated using a multi-unit base, enabling flexible selection to suit the system’s application and configuration.
Click here to download the comprehensive series catalog
![]() ![]() |
Convert to compatible signal among systems by insulating various kinds of DC signals.
Response time: 0.1 s or less/90%
Convert to compatible signal among systems by insulating various kinds of DC signals.
Response time: 500 μs or less/90%
Convert to compatible signal among systems by insulating various kinds of DC signals.
Response time: 180 μs or less/90%
Supplying power source to 2-wire system transmitter, receiving DC4-20mA signal from transmitter and outputting insulated proportional DC signal.
Insulating input/output and converting to DC signals in proportion to temperature with thermoelectromotive force of various kinds of thermocouple as input.
Insulating input/output and converting to DC signals in proportion to temperature with resistance value of 3-wire system resistance bulb as input.
By replacing mechanical angle and position displacement to resistance change of potentiometer as input and convert to DC signals in proportion to displacement by insulation.
With tachogenerator mounted to generator, etc. as input and convert to DC signals in proportion to revolution speed (frequency) by insulating between input and output.
Convert to DC signals in proportion to AC current in electric system.
Convert to DC signals in proportion to AC voltage in electric system.
Convert to compatible signal among systems by insulating various kinds of DC signals. As insulated 2 outputs can be extracted, controlling/monitoring are possible with 1 unit.
Response time: 0.1 s or less/90%
Convert to compatible signal among systems by insulating various kinds of DC signals. As insulated 2 outputs can be extracted, controlling/monitoring are possible with 1 unit.
Response time: 500 μs or less/90%
Convert to compatible signal among systems by insulating various kinds of DC signals. As insulated 2 outputs can be extracted, controlling/monitoring are possible with 1 unit.
Response time: 180 μs or less/90%
Supplying power source to 2-wire system transmitter, receiving DC4-20mA signal from transmitter and outputting insulated proportional DC signal. As insulated 2 outputs can be extracted, controlling/monitoring are possible with 1 unit.
Insulating input/output and converting to DC signals in proportion to temperature with thermoelectromotive force of various kinds of thermocouple as input. As insulated 2 outputs can be extracted, controlling/monitoring are possible with 1 unit.
Insulating input/output and converting to DC signals in proportion to temperature with resistance value of 3-wire system resistance temperature element as input. As insulated 2 outputs can be extracted, controlling/monitoring are possible with 1 unit.
By replacing mechanical angle and position displacement to resistance change of potentiometer as input and convert to DC signals in proportion to displacement by insulation. As insulated 2 outputs can be extracted, controlling/monitoring are possible with 1 unit.
With tachogenerator mounted to generator, etc. as input and convert to DC signals in proportion to revolution speed (frequency) by insulating between input and output. As insulated 2 outputs can be extracted, controlling/monitoring are possible with 1 unit.
Convert to DC signals in proportion to AC current in electric system. As insulated 2 outputs can be extracted, controlling/monitoring are possible with 1 unit.
With tachogenerator mounted to generator, etc. as input and convert to DC signals in proportion to revolution speed (frequency) by insulating between input and output. As insulated 2 outputs can be extracted, controlling/ monitoring are possible with 1 unit.
TO Productpage
This communication unit features mutually isolated inputs that isolate DC voltage or DC current inputs and convert them to RS-485 communication outputs (Modbus RTU). It is used to monitor analog signals from devices such as pressure and flow meters, as well as temperature and humidity sensors, using a PLC or similar system.
TO Productpage
This is a plug-in type Communication Unit that isolates DC voltage or DC current input and converts it to communication signal. This product is used to monitor pressure or flow meters, temperature or hygrometers and other analog signals via communication output (MODBUS RS-485).
Small sized plug-in transducers (1 output type) can be stored all together. Because of power supply from one source, wiring work can be reduced.
Small sized plug-in transducer 1 output type & 2 outputs type can be stored all together. Because of power supply from one source, wiring work can be reduced.
Small sized plug-in transducer 1 output type & 2 outputs type can be stored all together. Power supply from one source but on-off the power can be able to do separate.